Previous (return to product page)
Mini Dia-Vac Performance Sheet
ADI's Dia-Vac® Pumps can Pass Your Gas at the Speed of Need! Due to an increased interest in reducing the pressure, vacuum and/or flow on the Dia-Vac® pumps, our engineers designed a modified eccentric design. This allows you to customize your Dia-Vac® pump to meet your application requirements while at the same time increasing the diaphragm and bearing life. The normal eccentric size is .160 on the Mini and Micro Dia-Vac® Pumps. To order any of the reduced eccentric pumps, simply add the number '5' to the end of the model number plus the first two digits of the eccentric designation (example '19310TC5-08'). Please see How to Specify and Order Pumps at ADI or call the factory direct for more information.
Please note that the chart below is not meant to be read as a combination of pressure and vacuum at the same time, only pressure or vacuum.
Mini Dia-Vac®
Flow Averages
(Please click on individual eccentric size for performance curves. Please
note: the standard eccentric size for the Mini Pumps is .160)
Model # |
PSIG (Max Pressure) |
Bar (Max Pressure) |
InHg (Ultimate Vacuum) |
Mbar (Ultimate Vacuum) |
CFM (Max Flow) |
LPM (Max Flow) |
| M081 | 6.0 |
0.41 |
7.0 |
237 |
0.44 |
12.5 |
| M101 | 17.0 |
1.17 |
17.0 |
575 |
0.47 |
13.5 |
| M121 | 21.0 |
1.43 |
18.0 |
600 |
0.64 |
18 |
| M151 | 27.0 |
1.86 |
20.0 |
676 |
0.72 |
20.0 |
| M161 (std.) | 30.0 |
2.07 |
22.0 |
745 |
0.78 |
22.0 |
| Double (parallel) | 33.0 |
2.27 |
22.0 |
745 |
1.28 |
36.2 |
Notes:
|