ADI's Dia-Vac® Pumps can Pass Your Gas at the Speed of
Need! Due to an increased interest in reducing the pressure, vacuum and/or flow on the
Dia-Vac® pumps, our engineers designed a modified eccentric design. This allows you to
customize your Dia-Vac® pump to meet your application requirements while at the same time
increasing the diaphragm and bearing life. The normal eccentric size is 0.160 on the
Micro Dia-Vac® Pump.
Please note that the chart below is not meant to be read as a combination of pressure
and vacuum at the same time, only pressure or vacuum.
Micro Dia-Vac®
Performance
(Please click on individual eccentric for performance curves)
| Notes:
- Test results are averaged, and therefore should be considered
approximate.
- Tests performed with 316ss head, Teflon® diaphragm, 1/4 inch
diameter hose x 5 ft. line at 75° F, using a std. 3000 rpm motor at 60 Hz.
- These test results are for reference only, and are intended to help
provide information to the user when determining which pump to buy. Actual pump
performance will depend upon the users' applications.
- For 50 Hz operation, reduce output by 17%
|