Model 100, 110, S-110 & S-113  
Description
For OEM or laboratory applications, where an affordable flow sensor needs to be installed,
the Model 100 is an excellent choice. Its time-proven turbine design will
keep measuring accurately for years with little or no maintenance. It features a
0-5VDC output standard. A power adapter or cable assembly (below) is
required for operation.
The Model 110 Flo-Meters are
great for laboratory benchtop gas applications. An integrated 3½ digit flow rate
display informs the user of actual flow, and the 0-5VDC output can be interfaced to a data
acquisition system. A power adapter (USA unless specified) is included for
plug-and-go operation.
The Model S-110 and S-113
Flo-Meters have a wide variety of uses. They too incorporate an LCD, 3½ digit display of
flow rate, but can be less expensive than the Model 110. The S-110 has a plastic body with
acetal fittings, and the S-113 is constructed from brass & includes brass fittings. A
power adapter or cable assembly (below) is required.

Wetted Parts

Wetted Parts: Ryton® , acetal, sapphire,
glass, epoxy, Viton® O-rings standard.
EPDM O-rings available at an added cost.
The Model S-113 also contains brass.
Dimensions, (excluding fittings):
Model 100: 2.35"x1.65"x1.50"
Model S-110, S-113: 1.88"x3.00"x1.75"
Model 110: 5.00"x4.50"x5.00"

Ranges
Call for dimensions on units over 5 L/minute.
| 100 |
110 |
S-110 |
S-113 |
Flow Range |
Max. Pressure Drop |
Standard Fittings |
| 100-3 |
110-3 |
S-110-3 |
S-113-3 |
20-100 mL/minute |
20" water |
1/8" tube |
| 100-4 |
110-4 |
S-110-4 |
S-113-4 |
40-200 mL/minute |
8" water |
1/8" tube |
| 100-5 |
110-5 |
S-110-5 |
S-113-5 |
100-500 mL/minute |
2" water |
1/8" tube |
| 100-6 |
110-6 |
S-110-6 |
S-113-6 |
200-1000 mL/minute |
2" water |
1/8" tube |
| 100-7 |
110-7 |
S-110-7 |
S-113-7 |
0.4-2.0 L/minute |
2" water |
1/4" tube |
| 100-8 |
110-8 |
S-110-8 |
S-113-8 |
1.0-5.0 L/minute |
2" water |
1/4" tube |
| 100-9 |
110-9 |
S-110-9 |
S-113-9 |
2.0-10.0 L/minute |
3" water |
1/4" tube |
| 100-10 |
110-10 |
S-110-10 |
... |
4.0-20.0 L/minute |
3" water |
3/8" tube |
| 100-11 |
110-11 |
S-110-11 |
... |
10-50 L/minute |
3" water |
3/8" tube |
| 100-12 |
110-12 |
S-110-12 |
... |
20-100 L/minute |
3" water |
1/2" tube |
| 100-13 |
110-13 |
S-110-13 |
... |
40-200 L/minute |
5" water |
1/2" tube |
| 100-14 |
110-14 |
S-110-14 |
... |
100-500 L/minute |
20" water |
1/2" tube |

See detailed specifications
NIST Calibration Certificate is optional at an added cost.
All units calibrated for air unless specified; certain unusual gases or blends
may incur added costs. Call for details.
Units also available calibrated to English (SCFH) units; call for details.
Options and Accessories
100-17 Cable Assembly - 3 foot long cable terminated with pigtail leads.
Includes all cables for input/output.
S-PS-08 - 115VAC (USA) power adapter and output leads. Order S-PS-18 for
230VAC (European) applications.
Displays (for Model 100) - The Model 210R and 250 are compatible.